<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EdgeConneX &#8211; mylogs.cn</title>
	<atom:link href="https://mylogs.cn/tag/edgeconnex/feed/" rel="self" type="application/rss+xml" />
	<link>https://mylogs.cn</link>
	<description>发现、记录、分享</description>
	<lastBuildDate>Thu, 27 Aug 2026 20:54:18 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	
	<item>
		<title>两相液冷进 AI 机房：散热运维成本降三成</title>
		<link>https://mylogs.cn/%e4%b8%a4%e7%9b%b8%e6%b6%b2%e5%86%b7%e8%bf%9b-ai-%e6%9c%ba%e6%88%bf%ef%bc%9a%e6%95%a3%e7%83%ad%e8%bf%90%e7%bb%b4%e6%88%90%e6%9c%ac%e9%99%8d%e4%b8%89%e6%88%90/</link>
		
		<dc:creator><![CDATA[steve, zhang]]></dc:creator>
		<pubDate>Thu, 27 Aug 2026 20:54:18 +0000</pubDate>
				<category><![CDATA[科技]]></category>
		<category><![CDATA[Accelsius]]></category>
		<category><![CDATA[AI 基础设施]]></category>
		<category><![CDATA[EdgeConneX]]></category>
		<category><![CDATA[两相液冷]]></category>
		<category><![CDATA[数据中心]]></category>
		<category><![CDATA[液冷散热]]></category>
		<guid isPermaLink="false">https://mylogs.cn/%e4%b8%a4%e7%9b%b8%e6%b6%b2%e5%86%b7%e8%bf%9b-ai-%e6%9c%ba%e6%88%bf%ef%bc%9a%e6%95%a3%e7%83%ad%e8%bf%90%e7%bb%b4%e6%88%90%e6%9c%ac%e9%99%8d%e4%b8%89%e6%88%90/</guid>

					<description><![CDATA[随着 AI 高功耗芯片把数据中心推入液冷时代，一种名为&#8221;两相直触芯片液冷&#8221;的技术正在加 [&#8230;]]]></description>
										<content:encoded><![CDATA[<p class="wp-block-paragraph">随着 AI 高功耗芯片把数据中心推入液冷时代，一种名为&#8221;两相直触芯片液冷&#8221;的技术正在加速落地。据 Business Wire 报道，液冷企业 Accelsius 已将其商用产品 IR150 部署到数据中心运营商 EdgeConneX 位于美国休斯顿的全球培训中心，用于培训运维团队应对下一代 AI 基础设施。</p>

<h2 class="wp-block-heading">技术源自贝尔实验室</h2>

<p class="wp-block-paragraph">Accelsius 于 2022 年由 Innventure（纳斯达克代码：INV）创立，其 NeuCool 两相直触芯片液冷技术源自诺基亚贝尔实验室（Nokia Bell Labs），相关技术由贝尔实验室研发五年却未产品化，最终由 Accelsius 推向商用。此次部署的 IR150 被描述为业内首款完全集成的&#8221;IT 机柜加 CDU（冷却液分配单元）&#8221;一体产品。</p>

<figure data-wp-context="{&quot;imageId&quot;:&quot;6a90d2f5db8fa&quot;}" data-wp-interactive="core/image" data-wp-key="6a90d2f5db8fa" class="wp-block-image size-large wp-lightbox-container"><img fetchpriority="high" decoding="async" width="1536" height="1024" data-wp-class--hide="state.isContentHidden" data-wp-class--show="state.isContentVisible" data-wp-init="callbacks.setButtonStyles" data-wp-on--click="actions.showLightbox" data-wp-on--load="callbacks.setButtonStyles" data-wp-on--pointerdown="actions.preloadImage" data-wp-on--pointerenter="actions.preloadImageWithDelay" data-wp-on--pointerleave="actions.cancelPreload" data-wp-on-window--resize="callbacks.setButtonStyles" src="https://mylogs.cn/wp-content/uploads/2026/08/316f300d8ae5fcb8f54588e32ce26f96_header.webp" alt="AI 数据中心两相液冷示意图" class="wp-image-5517" srcset="https://mylogs.cn/wp-content/uploads/2026/08/316f300d8ae5fcb8f54588e32ce26f96_header.webp 1536w, https://mylogs.cn/wp-content/uploads/2026/08/316f300d8ae5fcb8f54588e32ce26f96_header-300x200.webp 300w, https://mylogs.cn/wp-content/uploads/2026/08/316f300d8ae5fcb8f54588e32ce26f96_header-1024x683.webp 1024w, https://mylogs.cn/wp-content/uploads/2026/08/316f300d8ae5fcb8f54588e32ce26f96_header-768x512.webp 768w" sizes="(max-width: 1536px) 100vw, 1536px" /><button
			class="lightbox-trigger"
			type="button"
			aria-haspopup="dialog"
			data-wp-bind--aria-label="state.thisImage.triggerButtonAriaLabel"
			data-wp-init="callbacks.initTriggerButton"
			data-wp-on--click="actions.showLightbox"
			data-wp-style--right="state.thisImage.buttonRight"
			data-wp-style--top="state.thisImage.buttonTop"
		>
			<svg xmlns="http://www.w3.org/2000/svg" width="12" height="12" fill="none" viewBox="0 0 12 12">
				<path fill="#fff" d="M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z" />
			</svg>
		</button><figcaption>图片来源：示意图（AI 生成）</figcaption></figure>

<h2 class="wp-block-heading">相变散热的原理</h2>

<p class="wp-block-paragraph">两相直触芯片液冷的核心，是用一种介电制冷剂（dielectric refrigerant）直接在芯片上的蒸发器（又称冷板）沸腾，吸收大量汽化潜热，蒸汽再被送往 CDU 冷凝回液体，形成闭环。与传统单相水冷&#8221;只是升温&#8221;不同，相变在恒温下带走更多热量，因此能应对最炙手可热的人工智能与高性能计算处理器。由于制冷剂不导电，即便泄漏也不会损伤电子元件，且可在比单相直触芯片液冷更高的设施水温下运行，从而获得更长自然冷却时长、降低数据中心 PUE。</p>

<h2 class="wp-block-heading">成本账：运维省三成</h2>

<p class="wp-block-paragraph">相比于单相直触芯片液冷，两相方案的优势落在账面上。据 Johnson Controls 对 Accelsius 的战略投资披露，两相直触芯片液冷可带来约 35% 的运维支出（OpEx）节省，以及 8% 至 17% 的总拥有成本（TCO）节省。IR150 把两相 CDU 直接集成进 IT 机箱，做到即插即用，既降低冷却系统复杂度与成本，又把故障域限制在单个机柜内。</p>

<h2 class="wp-block-heading">培训中心的意义</h2>

<p class="wp-block-paragraph">EdgeConneX 全球培训中心是一个真实运营的数据中心学习环境，目的是让服务团队在上岗前就获得贴近生产的实操训练。引入两相液冷课程后，运维人员、技术员与生态伙伴可以动手部署和维护面向 AI 工作负载的两相液冷系统。Accelsius 首席执行官 John Hewitt 表示，两相冷却因制冷剂架构带来的简化运维模式正持续获得采用势头，不同于传统单相系统需要在服务器冷却回路中做大量流体管理与维护，NeuCool 让维护团队把精力放在可用性与能效上。EdgeConneX 工程与运营执行副总裁 Brian Green 则称，该培训中心本就是为面向未来数据中心技术培养运维人员而建，加入两相液冷能让团队获得一项正成为 AI 基础设施核心的技术的实操经验。</p>

<h2 class="wp-block-heading">行业趋势</h2>

<p class="wp-block-paragraph">AI 算力密度持续攀升，正把全球数据中心从风冷推向液冷，两相液冷是其中的重要方向之一。在中国市场，智算中心同样面临高密散热压力，液冷也日益成为新建数据中心的主流配置方向。此次 Accelsius 与 EdgeConneX 的合作，折射出产业界为下一代高密 AI 负载储备液冷运维能力的共同动作。</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
